Network performance differences within an IP Instance vs. across IP Instances

When consolidating or co-locating multiple applications on the same system, inter-application network typically stays within the system, since the shared IP in the kernel recognizes that the destination address is on the same system, and thus loops it back up the stack without ever putting the data on a physical network. This has introduced some challenges for customers deploying Solaris Containers (specifically zones) where different Containers are on different subnets, and it is expected that traffic between them leaves the system (maybe through a router or fireall to restrict or monitor inter-tier traffic).

With IP Instances in Solaris Nevada build 57 and targeted for Solaris 10 7/07, there is the ability to configures zones with exclusive IP Instances, thus forcing all traffic leaving a zone out onto the network. This introduces additional network stack processing both on the transmit and the receive. Prompted by some customer questions regarding this, I performed a simple test to measure the difference.

On two systems, a V210 with two 1.336GHz CPUs and 8GB memory, and an x4200 with two dual-core Opteron XXXX and 8GB memory, I ran FTP transfers between zones. My switch is a Netgear GS716T Smart Switch with 1Gbps ports. The V210 has four bge interfaces and the x4200 has four e1000g interfaces.

I created four zones. Zones x1 and x2 have eXclusive IP Instances, while zones s1 and s2 have Shared IP Instances (IP is shared with the global zone). Both systems are running Solaris 10 7/07 build 06.

Relevant zonecfg info is a follows (all zones are sparse):


v210# zonecfg -z x1 info
zonename: x1
zonepath: /localzones/x1
...
ip-type: exclusive
net:
        address not specified
        physical: bge1

v210# zonecfg -z s1 info
zonename: s1
zonepath: /localzones/s1
...
ip-type: shared
net:
        address: 10.10.10.11/24
        physical: bge3
 
As a test user in each zone, I created a file using 'mkfile 1000m /tmp/file1000m'. Then I used ftp to transfer it between zones. No tuning was done whatsoever.

The results are as follows.

V210: (bge)

Exclusive to Exclusive
x1# /usr/bin/time ftp x2 << EOF\^Jcd /tmp\^Jbin\^Jput file1000m\^JEOF

real       17.0
user        0.2
sys        11.2

Exclusive to Shared
x1# /usr/bin/time ftp s2 << EOF\^Jcd /tmp\^Jbin\^Jput file1000m\^JEOF

real       17.3
user        0.2
sys        11.6

Shared to Shared
s2# /usr/bin/time ftp s1 << EOF\^Jcd /tmp\^Jbin\^Jput file1000m\^JEOF

real        6.6
user        0.1
sys         5.3


X4200: (e1000g)

Exclusive to Exclusive
x1# /usr/bin/time ftp x2 << EOF\^Jcd /tmp\^Jbin\^Jput file1000m\^JEOF

real        9.1
user        0.0
sys         4.0

Exclusive to Shared
x1# /usr/bin/time ftp s2 << EOF\^Jcd /tmp\^Jbin\^Jput file1000m\^JEOF

real        9.1
user        0.0
sys         4.1

Shared to Shared
s2# /usr/bin/time ftp s1 << EOF\^Jcd /tmp\^Jbin\^Jput file1000m\^JEOF

real        4.0
user        0.0
sys         3.5
I ran each test several times and picked a result that seemed average across the runs. Not very scientific, and a table might be nicer.

Something I noticed that surprised me was that time spent in IP and the driver is measurable on the V210 with bge, and much less so on the x4200 with e1000g.

About

stw

Search

Categories
Archives
« April 2014
SunMonTueWedThuFriSat
  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
   
       
Today