X

Oracle Customer Engineering & Advocacy Lab (CEAL) Blog covers BI Tech, EPM, BI Cloud and EPM Cloud.

OBIEE 11.1.1 - Increase Timeouts in Oracle HTTP Server (OHS) plug-in (mod_wl_ohs.conf)

If you are seeing "Failure of server APACHE bridge" error when try to open large BIP report. This is due to your current Oracle HTTP Server (OHS) timeout parameters defined in plug-in file that are reaching amount of time the plug-in waits for a response to a request from WebLogic Server.

For each <Location> section in OHS file mod_wl_ohs.conf, set the following timeouts for example:

<Location /analytics>
      SetHandler weblogic-handler
       WebLogicCluster <servername>:9704
       WLIOTimeoutSecs 6000
       WLSocketTimeoutSecs 600
</Location>

# BI Publisher
<Location /xmlpserver>
     SetHandler weblogic-handler
     WebLogicCluster <servername>:9704
     WLIOTimeoutSecs 6000
     WLSocketTimeoutSecs 600
</Location>



Be the first to comment