Wednesday Dec 09, 2009

Logzillas: to mirror or stripe?

The Hybrid Storage Pool integrates flash into the storage hierarchy in two specific ways: as a massive read cache and as fast log devices. For read cache devices, Readzillas, there's no need for redundant configurations; it's a clean cache so the data necessarily also resides on disk. For log devices, Logzillas, redundancy is essential, but how that translates to their configuration can be complicated. How to decide whether to stripe or mirror?

ZFS intent log devices

Logzillas are used as ZFS intent log devices (slogs in ZFS jargon). For certain synchronous write operations, data is written to the Logzilla so the operation can be acknowledged to the client quickly before the data is later streamed out to disk. Rather than the milliseconds of latency for disks, Logzillas respond in about 100μs. If there's a power failure or system crash before the data can be written to disk, the log will be replayed when the system comes back up, the only scenario in which Logzillas are read. Under normal operation they are effectively write-only. Unlike Readzillas, Logzillas are integral to data integrity and they are relied upon for data integrity in the case of a system failure.

A common misconception is that a non-redundant Logzilla configuration introduces a single point of failure into the system, however this is not the case since the data contained on the log devices is also held in system memory. Though that memory is indeed volatile, data loss could only occur if both the Logzilla failed and the system failed within a fairly small time window.

Logzilla configuration

While a Logzilla doesn't represent a single point of failure, redundant configurations are still desirable in many situations. The Sun Storage 7000 series implements the Hybrid Storage Pool, and offers several different redundant disk configurations. Some of those configurations add a single level of redundancy: mirroring and single-parity RAID. Others provide additional redundancy: triple-mirroring, double-parity RAID and triple-parity RAID. For disk configurations that provide double disk redundancy of better, the best practice is to mirror Logzillas to achieve a similar level of reliability. For singly redundant disk configurations, non-redundant Logzillas might suffice, but there are conditions such as a critically damaged JBOD that could affect both Logzilla and controller more or less simultaneously. Mirrored Logzillas add additional protection against such scenarios.

Note that the Logzilla configuration screen (pictured) includes a column for No Single Point of Failure (NSPF). Logzillas are never truly a single point of failure as previous discussed; instead, this column refers to the arrangement of Logzillas in JBODs. A value of true indicates that the configuration is resilient against JBOD failure.

The most important factors to consider when deciding between mirrored or striped Logzillas are the consequences of potential data loss. In a failure of Logzillas and controller, data will not be corrupted, but the last 5-30 seconds worth of transactions could be lost. For example, while it typically makes sense to mirror Logzillas for triple-parity RAID configurations, it may be that the data stored is less important and the implications for data loss not worthy of the cost of another Logzilla device. Conversely, while a mirrored or single-parity RAID disk configuration provides only a single level of redundancy, the implications of data loss might be such that the redundancy of volatile system memory is insufficient. Just as it's important to choose the appropriate disk configuration for the right balance of performance, capacity, and reliability, it's at least as important to take care and gather data to make an informed decision about Logzilla configurations.

Wednesday Sep 16, 2009

2009.Q3 Storage Configuration

Today we shipped our 2009.Q3 release. Amidst the many great new features, enhancements and bug fixes, we've added new storage profiles for triple-parity RAID and three-way mirroring. Here's an example on a 9 JBOD system of what you'll see in the updated storage configuration screen:



Note that the new Triple parity RAID, wide stripes option replaces the old Double parity RAID, wide stripes configuration. With RAID stripes that can easily be more than 40 disks wide, and resilver times that can be quite long as a result, we decided that the additional protection of triple-parity RAID trumped the very small space efficiency of double-parity RAID.

Ryan Matthews has updated the space calculator for the 7310 and 7410 to include the new profiles. Download the new update and give it a shot.

Tuesday Jul 21, 2009

Triple-Parity RAID-Z

Double-parity RAID, or RAID-6, is the de facto industry standard for storage; when I started talking about triple-parity RAID for ZFS earlier this year, the need wasn't always immediately obvious. Double-parity RAID, of course, provides protection from up to two failures (data corruption or the whole drive) within a RAID stripe. The necessity of triple-parity RAID arises from the observation that while hard drive capacity has roughly followed Kryder's law, doubling annually, hard drive throughput has improved far more modestly. Accordingly, the time to populate a replacement drive in a RAID stripe is increasing rapidly. Today, a 1TB SAS drive takes about 4 hours to fill at its theoretical peak throughput; in a real-world environment that number can easily double, and 2TB and 3TB drives expected this year and next won't move data much faster. Those long periods spent in a degraded state increase the exposure to the bit errors and other drive failures that would in turn lead to data loss. The industry moved to double-parity RAID because one parity disk was insufficient; longer resilver times mean that we're spending more and more time back at single-parity. From that it was obvious that double-parity will soon become insufficient. (I'm working on an article that examines these phenomena quantitatively so stay tuned... update Dec 21, 2009: you can find the article here)

Last week I integrated triple-parity RAID into ZFS. You can take a look at the implementation and the details of the algorithm here, but rather than describing the specifics, I wanted to describe its genesis. For double-parity RAID-Z, we drew on the work of Peter Anvin which was also the basis of RAID-6 in Linux. This work was more or less a tutorial for systems programers, simplifying some of the more subtle underlying mathematics with an eye towards optimization. While a systems programmer by trade, I have a background in mathematics so was interested to understand the foundational work. James S. Plank's paper A Tutorial on Reed-Solomon Coding for Fault-Tolerance in RAID-like Systems describes a technique for generalized N+M RAID. Not only was it simple to implement, but it could easily be made to perform well. I struggled for far too long trying to make the code work before discovering trivial flaws with the math itself. A bit more digging revealed that the author himself had published Note: Correction to the 1997 Tutorial on Reed-Solomon Coding 8 years later addressing those same flaws.

Predictably, the mathematically accurate version was far harder to optimize, stifling my enthusiasm for the generalized case. My more serious concern was that the double-parity RAID-Z code suffered some similar systemic flaw. This fear was quickly assuaged as I verified that the RAID-6 algorithm was sound. Further, from this investigation I was able to find a related method for doing triple-parity RAID-Z that was nearly as simple as its double-parity cousin. The math is a bit dense; but the key observation was that given that 3 is the smallest factor of 255 (the largest value representable by an unsigned byte) it was possible to find exactly of 3 different seed or generator values after which there were collections of failures that formed uncorrectable singularities. Using that technique I was able to implement a triple-parity RAID-Z scheme that performed nearly as well as the double-parity version.

As far as generic N-way RAID-Z goes, it's still something I'd like to add to ZFS. Triple-parity will suffice for quite a while, but we may want more parity sooner for a variety of reasons. Plank's revised algorithm is an excellent start. The test will be if it can be made to perform well enough or if some new clever algorithm will need to be devised. Now, as for what to call these additional RAID levels, I'm not sure. RAID-7 or RAID-8 seem a bit ridiculous and RAID-TP and RAID-QP aren't any better. Fortunately, in ZFS triple-parity RAID is just raidz3.

A little over three years ago, I integrated double-parity RAID-Z into ZFS, a feature expected of enterprise class storage. This was in the early days of Fishworks when much of our focus was on addressing functional gaps. The move to triple-parity RAID-Z comes in the wake of a number of our unique advancements to the state of the art such as DTrace-powered Analytics and the Hybrid Storage Pool as the Sun Storage 7000 series products meet and exceed the standards set by the industry. Triple-parity RAID-Z will, of course, be a feature included in the next major software update for the 7000 series (2009.Q3).

Tuesday May 26, 2009

Sun Storage 7310

Today we're introducing a new member to the Sun Unified Storage family: the Sun Storage 7310. The 7310 is a scalable system from 12TB with a single half-populated J4400 JBOD up to 96TB with 4 JBODs. You can combine two 7310 head units to form a cluster. The base configuration includes a single quad-core CPU, 16GB of DRAM, a SAS HBA, and two available PCIe slots for NICs, backup cards, or the Fishworks cluster card. The 7310 can be thought of as a smaller capacity, lower cost version of the Sun Storage 7410. Like the 7410 it uses high density, low power disks as primary storage and can be enhanced with Readzilla and Logzilla flash accelerators for high performance. Like all the 7000 series products, the 7310 includes all protocols and software features without license fees.

The 7310 is an entry-level clusterable, scalable storage server, but the performance is hardly entry-level. Brendan Gregg from the Fishworks team has detailed the performance of the 7410, and has published the results of those tests on the new 7310. Our key metrics are cached reads from DRAM, uncached reads from disk, and writes to disk all over two 10GbE links with 20 client systems. As shown in the graph, the 7310 is an absolute champ, punching well above its weight. The numbers listed are in units of MB/s. Notice that the recent 2009.Q2 software update brought significant performance improvements to the 7410, and that the 7310 holds its own. For owners of entry-level systems from other vendors, check for yourself, but the 7310 is a fire-breather.

Added to the low-end 7110, the dense, expandable 7210, the high-end clusterable, expandable 7410, the 7310 fills an important role in the 7000 series product line: an entry-level clusterable, expandable system, with impressive performance, and an attractive price. If the specs and performance have piqued your interest, try out the user interface on the 7000 series with the Sun Storage 7000 simulator.

Mirroring flash SSDs

As flash memory has become more and more prevalent in storage from the consumer to theenterprise people have been charmed by the performance characteristics, but get stuck on the longevity. SSDs based on SLC flash are typically rated at 100,000 to 1,000,000 write/erase cycles while MLC-based SSDs are rated for significantly less. For conventional hard drives, the distinct yet similar increase in failures over time has long been solved by mirroring (or other redundancy techniques). When applying this same solution to SSDs, a common concern is that two identical SSDs with identical firmware storing identical data would run out of write/erase cycles for a given cell at the same moment and thus data reliability would not be increased via mirroring. While the logic might seem reasonable, permit me to dispel that specious argument.

The operating system and filesystem

From the level of most operating systems or filesystems, an SSD appears like a conventional hard drive and is treated more or less identically (Solaris' ZFS being a notable exception). As with hard drives, SSDs can report predicted failures though SMART. For reasons described below, SSDs already keep track of the wear of cells, but one could imagine even the most trivial SSD firmware keeping track of the rapidly approaching write/erase cycle limit and notifying the OS or FS via SMART which would in turn the user. Well in advance of actual data loss, the user would have an opportunity to replace either or both sides of the mirror as needed.

SSD firmware

Proceeding down the stack to the level of the SSD firmware, there are two relevant features to understand: wear-leveling, and excess capacity. There is not a static mapping between the virtual offset of an I/O to an SSD and the physical flash cells that are chosen by the firmware to record the data. For a variety of reasons — flash call early mortality, write performance, bad cell remapping — it is necessary for the SSD firmware to remap data all over its physical flash cells. In fact, hard drives have a similar mechanism by which they hold sectors in reserve and remap them to fill in for defective sectors. SSDs have the added twist that they want to maximize the longevity of their cells each of which will ultimately decay over time. To do this, the firmware ensures that a given cell isn't written far more frequently than any other cell, a process called wear-leveling for obvious reasons.

To summarize, subsequent writes to the same LBA, the same virtual location, on an SSD could land on different physical cells for the several reasons listed. The firmware is, more often than not, deterministic thus two identical SSDs with the exact same physical media and I/O stream (as in a mirror) would behave identically, but minor timing variations in the commands from operating software, and differences in the media (described below) ensure that the identical SSDs will behave differently. As time passes, those differences are magnified such that two SSDs that started with the same mapping between virtual offsets and physical media will quickly and completely diverge.

Flash hardware and physics

Identical SSDs with identical firmware, still have their own physical flash memory which can vary in quality. To break the problem apart a bit, an SSD is composed of many cells, and each cell's ability to retain data slowly degrades as it's exercised. Each cell is in fact a physical component of an integrated circuit composed. Flash memory differs from many other integrated circuits in that it requires far higher voltages than others. It is this high voltage that causes the oxide layer to gradually degrade over time. Further, all cells are not created equal — microscopic variations in the thickness and consistency of the physical medium can make some cells more resilient and others less; some cells might be DOA, while others might last significantly longer than the norm. By analogy, if you install new light bulbs in a fixture, they might burn out in the same month, but how often do they fail on the same day? The variability of flash cells impacts the firmware's management of the underlying cells, but more trivially it means that two SSDs in a mirror would experience dataloss of corrsponding regions at different rates.

Wrapping up

As with conventional hard drives, mirroring SSDs is a good idea to preserve data integrity. The operating system, filesystem, SSD firmware, and physical properties of the flash medium make this approach sound both in theory and in practice. Flash is a new exciting technology and changes many of the assumptions derived from decades of experience with hard drives. As always proceed with care — especially when your data is at stake — but get the facts, and in this case the wisdom of conventional hard drives still applies.

Monday May 04, 2009

SS 7000 simulator update plus VirtualBox

On the heels of the 2009.Q2.0.0 release, we've posted an update to the Sun Storage 7000 simulator. The simulator contains the exact same software as the other members of the 7000 series, but runs inside a VM rather than on actual hardware. It supports all the same features, and has all the same UI components; just remember that an actual 7000 series appliance is going to perform significantly better than a VM running a puny laptop CPU. Download the simulator here.

The new version of the simulator contains two enhancements. First, it comes with the 2009.Q2.0.0 release pre-installed. The Q2 release is the first to provide full support for the simulator, and as I wrote here you can simply upgrade your old simulator. In addition, while the original release of the simulator could only be run on VMware we now support both VMware and VirtualBox (version 2.2.2 or later). When we first launched the 7000 series back in November, we intended to support the simulator on VirtualBox, but a couple of issues thwarted us, in particular lack of OVF support and host-only networking. The recent 2.2.2 release of VirtualBox brought those missing features, so we're pleased to be able to support both virtualization platforms.

As OVF support is new in VirtualBox, here's a quick installation guide for the simulator. After uncompressing the SunStorageVBox.zip archive, select "Import Appliance...", and select "Sun Storage VirtualBox.ovf". Clicking through will bring up a progress bar. Be warned: this can take a while depending on the speed of your CPU and hard drive.

When that completes, you will see the "Sun Storage VirtualBox" VM in the VirtualBox UI. You may need to adjust settings such as the amount of allocated memory, or extended CPU features. Run the VM and follow the instructions when it boots up. You'll be prompted for some simple network information. If you're unsure how to fill in some of the fields, here are some pointers:

  • Host Name - whatever you want
  • DNS Domain - "localdomain"
  • Default Router - the same as the IP address but put 1 as the final octet
  • DNS Server - the same as the IP address but put 1 as the final octet
  • Password - whatever you want and something you can remember

When you complete that form, wait until you're given a URL to copy into a web browser. Note that you'll need to use the version of the URL with the IP address (unless you've added an entry to your DNS server). In the above example, that would be: https://192.168.56.101:215/. From the web browser, complete the appliance configuration, and then you can start serving up data, observing activity with Storage Analytics, and kicking the tires on a functional replica of a 7000 series appliance.

Monday Apr 27, 2009

Sun Storage 7000 simulator upgrade

Today we released version 2009.Q2.0.0, the first major software update for the Sun Storage 7000 series. It includes a bunch of new features, bug fixes, and improvements. Significantly for users of the Sun Storage 7000 simulator, the virtual machine version of the 7000 series, this is the first update that supports the VMs. As with a physical 7000 series appliance, upgrade by navigating to Maintenance > System, and click the + icon next to Available Updates. Remember not to ungzip the update binary — the appliance will do that itself. We'll be releasing an update VM preinstalled with the new bits so stay tuned.

Note: There were actually two releases of the VMware simulator. The first one came right around our initial launch, and the version string is ak-2008.11.07. This version cannot be upgraded so you'll need to download the updated simulator whose version is ak-2008.11.21. As noted above, we'll soon be releasing an updated VM with 2009.Q2.0.0 (ak-2009.04.10.0.0) preinstalled.

Friday Mar 06, 2009

Fishworks VM: the 7000 series on your laptop

In May of 2007 I was lined up to give my first customer presentation of what would become the Sun Storage 7000 series. I inherited a well-worn slide deck describing the product, but we had seen the reactions of prospective customers who saw the software live and had a chance to interact with features such as Analytics; no slides would elicit that kind of response. So with some tinkering, I hacked up our installer and shoe-horned the prototype software into a virtual machine. The live demonstration was a hit despite some rocky software interactions.

As the months passed, our software became increasingly aware of our hardware platforms; the patches I had used for the virtual machine version fell into disrepair. Racing toward the product launch, neither I nor anyone else in the Fishworks group had the time to nurse it back to health. I found myself using months old software for a customer demo — a useful tool, but embarrassing given the advances we had made. We knew that the VM was going to be great for presentations, and we had talked about releasing a version to the general public, but that, we thought, was something that we could sort out after the product launch.

In the brief calm after the frenetic months finishing the product and just a few days before the launch in Las Vegas, our EVP of storage, John Fowler, paid a visit to the Fishworks office. When we mentioned the VM version, his eyes lit up at the thought of how it would help storage professionals. Great news, but we realized that the next few days had just become much busier.

Creating the VM version was a total barn-raising. Rather than a one-off with sharp edges, adequate for a canned demo, we wanted to hand a product to users that would simulate exactly a Sun Storage 7000 series box. In about three days, everyone in the group pitched in to build what was essentially a brand new product and platform complete with a hardware view conjured from bits of our actual appliances.

After a frenetic weekend in November, the Sun Unified Storage Simulator was ready in time for the launch. You can download it here for VMware. We had prepared versions for VirtualBox as well as VMware, preferring VirtualBox since it's a Sun product; along the way we found some usability issues with the VirtualBox version — we were pushing both products beyond their design center and VMware handled it better. Rest assured that we're working to resolve those issues and we'll release the simulator for VirtualBox just as soon as it's ready. Note that we didn't limit the functionality at all; what you see is exactly what you'll get with an actual 7000 series box (though the 7000 series will deliver much better performance than a laptop). Analytics, replication, compression, CIFS, iSCSI are all there; give it a try and see what you think.

Monday Feb 23, 2009

HSP talk at the OpenSolaris Storage Summit

The organizers of the OpenSolaris Storage Summit asked me to give a presentation about Hybrid Storage Pools and ZFS. You can download the presentation titled ZFS, Cache, and Flash. In it, I talk about flash as a new caching tier in the storage hierarchy, some of the innovations in ZFS to enable the HSP, and an aside into the how we implement an HSP in the Sun Storage 7410.

Monday Dec 01, 2008

Casting the shadow of the Hybrid Storage Pool

The debate, calmly waged, on the best use of flash in the enterprise can be summarized as whether flash should be a replacement for disk, acting as primary storage, or it should be regarded as a new, and complementary tier in the storage hierarchy, acting as a massive read cache. The market leaders in storage have weighed in the issue, and have declared incontrovertibly that, yes, both are the right answer, but there's some bias underlying that equanimity. Chuck Hollis, EMC's Global Marketing CTO, writes, that "flash as cache will eventually become less interesting as part of the overall discussion... Flash as storage? Well, that's going to be really interesting." Standing boldly with a foot in each camp, Dave Hitz, founder and EVP at Netapp, thinks that "Flash is too expensive to replace disk right away, so first we'll see a new generation of storage systems that combine the two: flash for performance and disk for capacity." So what are these guys really talking about, what does the landscape look like, and where does Sun fit in all this?

Flash as primary storage (a.k.a. tier 0)

Integrating flash efficiently into a storage system isn't obvious; the simplest way is as a direct replacement for disks. This is why most of the flash we use today in enterprise systems comes in units that look and act just like hard drives: SSDs are designed to be drop in replacements. Now, a flash SSD is quite different than a hard drive — rather than a servo spinning platters while a head chatters back and forth, an SSD has floating gates arranged in blocks... actually it's probably simpler to list what they have in common, and that's just the form factor and interface (SATA, SAS, FC). Hard drives have all kind of properties that don't make sense in the world of SSDs (e.g. I've seen an SSD that reports it's RPM telemetry as 1), and SSDs have their own quirks with no direct analog (read/write asymmetry, limited write cycles, etc). SSD venders, however, manage to pound these round pegs into their square holes, and produce something that can stand in for an existing hard drive. Array vendors are all too happy to attain buzzword compliance by stuffing these SSDs into their products.

The trouble with HSM is the burden of the M.

Storage vendors already know how to deal with a caste system for disks: they striate them in layers with fast, expensive 15K RPM disks as tier 1, and slower, cheaper disks filling out the chain down to tape. What to do with these faster, more expensive disks? Tier-0 of course! An astute Netapp blogger asks, "when the industry comes up with something even faster... are we going to have tier -1" — great question. What's wrong with that approach? Nothing. It works; it's simple; and we (the computing industry) basically know how to manage a bunch of tiers of storage with something called hierarchical storage management. The trouble with HSM is the burden of the M. This solution kicks the problem down the road, leaving administrators to figure out where to put data, what applications should have priority, and when to migrate data.

Flash as a cache

The other school of thought around flash is to use it not as a replacement for hard drives, but rather as a massive cache for reading frequently accessed data. As I wrote back in June for CACM, "this new flash tier can be thought of as a radical form of hierarchical storage management (HSM) without the need for explicit management. Tersely, HSM without the M. This idea forms a major component of what we at Sun are calling the Hybrid Storage Pool (HSP), a mechanism for integrating flash with disk and DRAM to form a new, and — I argue — superior storage solution.

Let's set aside the specifics of how we implement the HSP in ZFS — you can read about that elsewhere. Rather, I'll compare the use of flash as a cache to flash as a replacement for disk independent of any specific solution.

The case for cache

It's easy to see why using flash as primary storage is attractive. Flash is faster than the fastest disks by at least a factor of 10 for writes and a factor of 100 for reads measured in IOPS. Replacing disks with flash though isn't without nuance; there are several inhibitors, primary among them is cost. The cost of flash continues to drop, but it's still much more expensive than cheap disks, and will continue to be for quite awhile. With flash as primary storage, you still need data redundancy — SSDs can and do fail — and while we could use RAID with single- or double-device redundancy, that would cleave the available IOPS by a factor of the stripe width. The reason to migrate to flash is for performance so it wouldn't make much sense to hang a the majority of that performance back with RAID. The remaining option, therefore, is to mirror SSDs whereby the already high cost is doubled.

It's hard to argue with results, all-flash solutions do rip. If money were no object that may well be the best solution (but if cost truly wasn't a factor, everyone would strap batteries to DRAM and call it a day).

Can flash as a cache do better? Say we need to store a 50TB of data. With an all-flash pool, we'll need to buy SSDs that can hold roughly 100TB of data if we want to mirror for optimal performance, and maybe 60TB if we're willing to accept a far more modest performance improvement over conventional hard drives. Since we're already resigned to cutting a pretty hefty check, we have quite a bit of money to play with to design a hybrid solution. If we were to provision our system with 50TB of flash and 60TB of hard drives we'd have enough cache to retain every byte of active data in flash while the disks provide the necessary redundancy. As writes come in the filesystem would populate the flash while it writes data persistently to disk. The performance of this system would be epsilon away from the mirrored flash solution as read requests would only go to disk in the case of faults from the flash devices. Note that we never rely on correctness from the flash; it's the hard drives that provide reliability.

The performance of this system would be epsilon away from the mirrored flash solution...

The hybrid solution is cheaper, and it's also far more flexible. If a smaller working set accounted for a disproportionally large number of reads, the total IOPS capacity of the all-flash solution could be underused. With flash as a cache, data could be migrated to dynamically distribute load, and additional cache could be used to enhance the performance of the working set. It would be possible to use some of the same techniques with an all-flash storage pool, but it could be tricky. The luxury of a cache is that the looser contraints allow for more aggressive data manipulation.

Building on the idea of concentrating the use of flash for hot data, it's easy to see how flash as a cache can improve performance even without every byte present in the cache. Most data doesn't require 50μs random access latency over the entire dataset, users would see a significant performance improvement with just the active subset in a flash cache. Of course, this means that software needs to be able to anticipate what data is in use which probably inspired this comment from Chuck Hollis: "cache is cache — we all know what it can and can't do." That may be so, but comparing an ocean of flash for primary storage to a thimbleful of cache reflects fairly obtuse thinking. Caching algorithms will always be imperfect, but the massive scale to which we can grow a flash cache radically alters the landscape.

Even when a working set is too large to be cached, it's possible for a hybrid solution to pay huge dividends. Over at Facebook, Jason Sobel (a colleague of mine in college) produced an interesting presentation on their use of storage (take a look at Jason's penultimate slide for his take on SSDs). Their datasets are so vast and sporadically accessed that the latency of actually loading a picture, say, off of hard drives isn't actually the biggest concern, rather it's the time it takes to read the indirect blocks, the metadata. At facebook, they've taken great pains to reduce the number of dependent disk accesses from fifteen down to about three. In a case such as theirs, it would never be economical store or cache the full dataset on flash and the working set is similarly too large as data access can be quite unpredictable. It could, however, be possible to cache all of their metadata in flash. This would reduce the latency to an infrequently accessed image by nearly a factor of three. Today in ZFS this is a manual setting per-filesystem, but it would be possible to evolve a caching algorithm to detect a condition where this was the right policy and make the adjustment dynamically.

Using flash as a cache offers the potential to do better, and to make more efficient and more economical use of flash. Sun, and the industry as a whole have only just started to build the software designed to realize that potential.

Putting products before words

At Sun, we've just released our first line of products that offer complete flash integration with the Hybrid Storage Pool; you can read about that in my blog post on the occassion of our product launch. On the eve of that launch, Netapp announced their own offering: a flash-laden PCI card that plays much the same part as their DRAM-based Performance Acceleration Module (PAM). This will apparently be available sometime in 2009. EMC offers a tier 0 solution that employs very fast and very expensive flash SSDs.

What we have in ZFS today isn't perfect. Indeed, the Hybrid Storage Pool casts the state of the art forward, and we'll be catching up with solutions to the hard questions it raises for at least a few years. Only then will we realize the full potential of flash as a cache. What we have today though integrates flash in a way that changes the landscape of storage economics and delivers cost efficiencies that haven't been seen before. If the drives manufacturers don't already, it can't be long until they hear the death knell for 15K RPM drives loud and clear. Perhaps it's cynical or solipsistic to conclude that the timing of Dave Hitz's and Chuck Hollis' blogs were designed to coincide with the release of our new product and perhaps take some of the wind out of our sails, but I will — as the commenters on Dave's Blog have — take it as a sign that we're on the right track. For the moment, I'll put my faith in this bit of marketing material enigmatically referenced in a number of Netapp blogs on the subject of flash:

In today's competitive environment, bringing a product or service to market faster than the competition can make a significant difference. Releasing a product to market in a shorter time can give you first-mover advantage and result in larger market share and higher revenues.

Wednesday Nov 19, 2008

Sun Storage 7410 space calculator

The Sun Storage 7410 is our expandable storage appliance that can be hooked up to anywhere from one and twelve JBODs with 24 1TB disks. With all those disks we provide the several different options for how to arrange them into your storage pool: double-parity RAID-Z, wide-strip double-parity RAID-Z, mirror, striped, and single-parity RAID-Z with narrow stripes. Each of these options has a different mix of availability, performance, and capacity that are described both in the UI and in the installation documentation. With the wide array of supported configurations, it can be hard to know how much usable space each will support.

To address this, I wrote a python script that presents a hypothetical hardware configuration to an appliance and reports back the available options. We use the logic on the appliance itself to ensure that the results are completely accurate as the same algorithms would be applied as when then the physical pallet of hardware shows up. This, of course, requires you to have an appliance available to query — fortunately, you can run a virtual instance of the appliance on your laptop.

You can download the sizecalc.py here; you'll need python installed on the system where you run it. Note that the script uses XML-RPC to interact with the appliance, and consequently it relies on unstable interfaces that are subject to change. Others are welcome to interact with the appliance at the XML-RPC layer, but note that it's unstable and unsupported. If you're interested in scripting the appliance, take a look at Bryan's recent post. Feel free to post comments here if you have questions, but there's no support for the script, implied, explicit, unofficial or otherwise.

Running the script by itself produces a usage help message:

$ ./sizecalc.py
usage: ./sizecalc.py [ -h <half jbod count> ] <appliance name or address>
    <root password> <jbod count>
Remember that you need a Sun Storage 7000 appliance (even a virtual one) to execute the capacity calculation. In this case, I'll specify a physical appliance running in our lab, and I'll start with a single JBOD (note that I've redacted the root password, but of course you'll need to type in the actual root password for your appliance):
$ ./sizecalc.py catfish \*\*\*\*\* 1
type            NSPF   width  spares   data drives     capacity (TB)
raidz2         False      11       2            22                18
raidz2 wide    False      23       1            23                21
mirror         False       2       2            22                11
stripe         False       0       0            24                24
raidz1         False       4       4            20                15
Note that with only one JBOD no configurations support NSPF (No Single Point of Failure) since that one JBOD is always a single point of failure. If we go up to three JBODs, we'll see that we have a few more options:
$ ./sizecalc.py catfish \*\*\*\*\* 3
type            NSPF   width  spares   data drives     capacity (TB)
raidz2         False      13       7            65                55
raidz2          True       6       6            66                44
raidz2 wide    False      34       4            68                64
raidz2 wide     True       6       6            66                44
mirror         False       2       4            68                34
mirror          True       2       4            68                34
stripe         False       0       0            72                72
raidz1         False       4       4            68                51
In this case we have to give up a bunch of capacity in order to attain NSPF. Now let's look at the largest configuration we support today with twelve JBODs:
$ ./sizecalc.py catfish \*\*\*\*\* 12
type            NSPF   width  spares   data drives     capacity (TB)
raidz2         False      14       8           280               240
raidz2          True      14       8           280               240
raidz2 wide    False      47       6           282               270
raidz2 wide     True      20       8           280               252
mirror         False       2       4           284               142
mirror          True       2       4           284               142
stripe         False       0       0           288               288
raidz1         False       4       4           284               213
raidz1          True       4       4           284               213

The size calculator also allows you to model a system with Logzilla devices, write-optimized flash devices that form a key part of the Hybrid Storage Pool. After you specify the number of JBODs in the configuration, you can include a list of how many Logzillas are in each JBOD. For example, the following invocation models twelve JBODs with four Logzillas in the first 2 JBODs:

$ ./sizecalc.py catfish \*\*\*\*\* 12 4 4
type            NSPF   width  spares   data drives     capacity (TB)
raidz2         False      13       7           273               231
raidz2          True      13       7           273               231
raidz2 wide    False      55       5           275               265
raidz2 wide     True      23       4           276               252
mirror         False       2       4           276               138
mirror          True       2       4           276               138
stripe         False       0       0           280               280
raidz1         False       4       4           276               207
raidz1          True       4       4           276               207

A very common area of confusion has been how to size Sun Storage 7410 systems, and the relationship between the physical storage and the delivered capacity. I hope that this little tool will help to answer those questions. A side benefit should be still more interest in the virtual version of the appliance — a subject I've been meaning to post about so stay tuned.

Update December 14, 2008: A couple of folks requested that the script allow for modeling half-JBOD allocations because the 7410 allows you to split JBODs between heads in a cluster. To accommodate this, I've added a -h option that takes as its parameter the number of half JBODs. For example:

$ ./sizecalc.py -h 12 192.168.18.134 \*\*\*\*\* 0
type            NSPF   width  spares   data drives     capacity (TB)
raidz2         False      14       4           140               120
raidz2          True      14       4           140               120
raidz2 wide    False      35       4           140               132
raidz2 wide     True      20       4           140               126
mirror         False       2       4           140                70
mirror          True       2       4           140                70
stripe         False       0       0           144               144
raidz1         False       4       4           140               105
raidz1          True       4       4           140               105

Update February 4, 2009: Ryan Matthews and I collaborated on a new version of the size calculator that now lists the raw space available in TB (decimal as quoted by drive manufacturers for example) as well as the usable space in TiB (binary as reported by many system tools). The latter also takes account of the sliver (1/64th) reserved by ZFS:

$ ./sizecalc.py 192.168.18.134 \*\*\*\*\* 12
type          NSPF  width spares  data drives       raw (TB)   usable (TiB)
raidz2       False     14      8          280         240.00         214.87
raidz2        True     14      8          280         240.00         214.87
raidz2 wide  False     47      6          282         270.00         241.73
raidz2 wide   True     20      8          280         252.00         225.61
mirror       False      2      4          284         142.00         127.13
mirror        True      2      4          284         142.00         127.13
stripe       False      0      0          288         288.00         257.84
raidz1       False      4      4          284         213.00         190.70
raidz1        True      4      4          284         213.00         190.70

Update June 17, 2009: Ryan Matthews with help from has again revised the size calculator to model both adding expansion JBODs and to account for the now expandable Sun Storage 7210. Take a look at Ryan's post for usage information. Here's an example of the output:

$ ./sizecalc.py 172.16.131.131 \*\*\* 1 h1 add 1 h add 1 
Sun Storage 7000 Size Calculator Version 2009.Q2
type          NSPF  width spares  data drives       raw (TB)   usable (TiB)
mirror       False      2      5           42          21.00          18.80
raidz1       False      4     11           36          27.00          24.17
raidz2       False  10-11      4           43          35.00          31.33
raidz2 wide  False  10-23      3           44          38.00          34.02
stripe       False      0      0           47          47.00          42.08

Update September 16, 2009: Ryan Matthews updated the size calculator for the 2009.Q3 release. The update includes the new triple-parity RAID wide stripe and three-way mirror profiles:

$ ./sizecalc.py boga \*\*\* 4
Sun Storage 7000 Size Calculator Version 2009.Q3
type          NSPF  width spares  data drives       raw (TB)   usable (TiB)
mirror       False      2      4           92          46.00          41.18
mirror        True      2      4           92          46.00          41.18
mirror3      False      3      6           90          30.00          26.86
mirror3       True      3      6           90          30.00          26.86
raidz1       False      4      4           92          69.00          61.77
raidz1        True      4      4           92          69.00          61.77
raidz2       False     13      5           91          77.00          68.94
raidz2        True      8      8           88          66.00          59.09
raidz2 wide  False     46      4           92          88.00          78.78
raidz2 wide   True      8      8           88          66.00          59.09
raidz3 wide  False     46      4           92          86.00          76.99
raidz3 wide   True     11      8           88          64.00          57.30
stripe       False      0      0           96          96.00          85.95

\*\* As of 2009.Q3, the raidz2 wide profile has been deprecated.
\*\* New configurations should use the raidz3 wide profile.

Sunday Nov 09, 2008

Hybrid Storage Pools in the 7410

The Sun Storage 7000 Series launches today, and with it Sun has the world's first complete product that seamlessly adds flash into the storage hierarchy in what we call the Hybrid Storage Pool. The HSP represents a departure from convention, and a new way of thinking designing a storage system. I've written before about the principles of the HSP, but now that it has been formally announced I can focus on the specifics of the Sun Storage 7000 Series and how it implements the HSP.

Sun Storage 7410: The Cadillac of HSPs

The best example of the HSP in the 7000 Series is the 7410. This product combines a head unit (or two for high availability) with as many as 12 J4400 JBODs. By itself, this is a pretty vanilla box: big, economical, 7200 RPM drives don't win any races, and the maximum of 128GB of DRAM is certainly a lot, but some workloads will be too big to fit in that cache. With flash, however, this box turns into quite the speed demon.

Logzilla

The write performance of 7200 RPM drive isn't terrific. The appalling thing is that the next best solution — 15K RPM drives — aren't really that much better: a factor of two or three at best. To blow the doors off, the Sun Storage 7410 allows up to four write-optimized flash drives per JBOD each of which is capable of handling 10,000 writes per second. We call this flash device Logzilla.

Logzilla is a flash-based SSD that contains a pretty big DRAM cache backed by a supercapacitor so that the cache can effectively be treated as nonvolatile. We use Logzilla as a ZFS intent log device so that synchronous writes are directed to Logzilla and clients incur only that 100μs latency. This may sound a lot like how NVRAM is used to accelerate storage devices, and it is, but there are some important advantages of Logzilla. The first is capacity: most NVRAM maxes out at 4GB. That might seem like enough, but I've talked to enough customers to realize that it really isn't and that performance cliff is an awful long way down. Logzilla is an 18GB device which is big enough to hold the necessary data while ZFS syncs it out to disk even running full tilt. The second problem with NVRAM scalability: once you've stretched your NVRAM to its limit there's not much you can do. If your system supports it (and most don't) you can add another PCI card, but those slots tend to be valuable resources for NICs and HBAs, and even then there's necessarily a pretty small number to which you could conceivably scale. Logzilla is an SSD sitting in a SAS JBOD so it's easy to plug more devices into ZFS and use them as a growing pool of intent log devices.

Readzilla

The standard practice in storage systems is to use the available DRAM as a read cache for data that is likely to be frequently accessed, and the 7000 Series does the same. In fact, it can do quite a better job of it because, unlike most storage systems which stop at 64GB of cache, the 7410 has up to 256GB of DRAM to use as a read cache. As I mentioned before, that's still not going to be enough to cache the entire working set for a lot of use cases. This is where we at Fishworks came up with the innovative solution of using flash as a massive read cache. The 7410 can accomodate up to six 100GB, read-optimized, flash SSDs; accordingly, we call this device Readzilla.

With Readzilla, a maximum 7410 configuration can have 256GB of DRAM providing sub-μs latency to cached data and 600GB worth of Readzilla servicing read requests in around 50-100μs. Forgive me for stating the obvious: that's 856GB of cache &mdash. That may not suffice to cache all workloads, but it's certainly getting there. As with Logzilla, a wonderful property of Readzilla is its scalability. You can change the number of Readzilla devices to match your workload. Further, you can choose the right combination of DRAM and Readzilla to provide the requisite service times with the appopriate cost and power use. Readzilla is cheaper and less power-hungry than DRAM so applications that don't need the blazing speed of DRAM can prefer the more economical flash cache. It's a flexible solution that can be adapted to specific needs.

Putting It All Together

We started with DRAM and 7200 RPM disks, and by adding Logzilla and Readzilla the Sun Storage 7410 also has great write and read IOPS. Further, you can design the specific system you need with just the right balance of write IOPS, read IOPS, throughput, capacity, power-use, and cost. Once you have a system, the Hybrid Storage Pool lets you solve problems with targeted solutions. Need capacity? Add disk. Out of read IOPS? Toss in another Readzilla or two. Write bogging down? Another Logzilla will net you another 10,000 write IOPS. In the old model, of course, all problems were simple because the solution was always the same: buy more fast drives. The HSP in the 7410 lets you address the specific problem you're having without paying for a solution to three other problems that you don't have.

Of course, this means that administrators need to better understand the performance limiters, and fortunately the Sun Storage 7000 Series has a great answer to that in Analytics. Pop over to Bryan's blog where he talks all about that feature of the Fishworks software stack and how to use it to find performance problems on the 7000 Series. If you want to read more details about Hybrid Storage Pools and how exactly all this works, take a look my article on the subject in CACM, as well as this post about the L2ARC (the magic behind using Readzilla) and a nice marketing pitch on HSPs.